Temperature sensor with IP67 protection for outdoor usage.
Specifications:
•3m PVC cable
•IP67 Stainless steel 17241 casing
•Certificated for use in pharmaceutical or food industry
•-50°C to +125°C
Applications:
•Outdoor temperature monitoring
•Measuring of temperature in pharmaceutical and food industry
Pt-100 temperature sensor with 1-Wire UNI output. It contains a Pt-100 probe, 2m silicon cable, and a 1-Wire UNI converter.
Specifications:
•2m silicon cable
•IP67 Stainless steel casing
•Measuring accuracy ± 0.3°C
•-50°C to +200°C
Applications:
•Fire detection in buildings
•Temperature monitoring in freezers
•Outdoor temperature monitoring
Pt-100 low temperatures sensor with 1-Wire UNI output. It contains a Pt-100 probe, 2m PTFE covered cable, and a 1-Wire UNI converter.
Specifications:
•2m PTFE cable
•IP67 Stainless steel casing
•Measuring accuracy ± 0.3°C
•-190°C to +150°C
Applications:
•Temperature monitoring in freezers
•Measuring of temperature in pharmaceutical and food industry
•Outdoor temperature monitoring
Temperature sensor with calibration certificate in 3 points (-5°C, 25°C and 78°C).
Specifications:
•3m cable
•Measuring accuracy ± 0.3°C
•-10°C to +80°C
Applications:
•Food industry precise measurement
•Pharmaceutical industry with high precision
•Technological premises with calibration of values
Wall mount temperature and humidity sensor.
Specifications:
•Sensor can be mounted to a wall
•Measuring accuracy 5% RH
•0 to 100% RH
•Measuring accuracy ± 0.8°C
•-10°C to +80°C
Applications:
•Monitoring of temperature and humidity in ICT rooms and offices
•Monitoring of temperature and humidity in storage houses
Combined temperature and humidity sensor for ICT racks.
Specifications:
•19" Rack mount plate
•Can be daisy-chained
•Measuring accuracy 5% RH
•0 to 100% RH
•Measuring accuracy ± 0.8°C
•-10°C to +80°C
Applications:
•Humidity and temperature measuring in ICT racks
•Humidity and temperature measuring in server rooms
Combined temperature and humidity sensor for vertical wall mounting indoor usage.
Specifications:
•RS-485 bus provides ranges up to 1000 m
•Designed for the Poseidon2 4002
•Measuring accuracy 5% RH
•0 to 100% RH
•Measuring accuracy ± 0.8°C
•-10°C to +70°C
Applications:
•Wide-range monitoring systems with number of measurement points
•Food manufacturing and processing
•Temperature and humidity monitoring of medical material and pharmaceutical stores
Industrial temperature sensor in a box for RS-485 bus for Poseidon2 4002.
Specifications:
•Indoor or outdoor use, IP65, wall mount
•Measuring accuracy ± 0.25°C
•-30°C to +70°C
Applications:
•Wide-range monitoring systems with number of measurement points
•Typical applications include measuring temperature in places that can be flooded with water, or an environment with moisture condensation.
Industrial high temperature sensor on a cable for RS-485 bus for Poseidon2 4002.
Specifications:
•Indoor or outdoor use, IP65, wall mount
•Stainless steel housing on 2m cable
•Measuring accuracy ± 0.25°C
•-50°C to +200°C
Applications:
•Temeprature monitoring in civil engineering and industrial ovens
•Typical applications include measuring temperature in places that can be flooded with water, or an environment with moisture condensation.
Industrial low temperature sensor on a cable for RS-485 bus for Poseidon2 4002.
Specifications:
•Indoor or outdoor use, IP65, wall mount
•Stainless steel housing on 2m cable
•Measuring accuracy ± 0.25°C
•-190°C to +150°C
Applications:
•Temperature monitoring in pharmaceutical or freezing works.
•Accurate temperature monitoring in food processing
Water leak detection cable A - 2m for use with HWg-WLD and HWg-WLD Relay.
Specifications:
•2m detection cable
•Detects water, ethylene glycol
•Detection cable can be dried and reused
Applications:
•Universal water detection in any environment.
•Can be put on the floor, wrapped around pipes, or attached to a wall.
Water leak detection cable A - 10m for use with HWg-WLD and HWg-WLD Relay.
Specifications:
•10m detection cable
•Detects water, ethylene glycol
•Detection cable can be dried and reused
Applications:
•Universal water detection in any environment.
•Can be put on the floor, wrapped around pipes, or attached to a wall.
Water leak detection cable A - 50m for use with HWg-WLD and HWg-WLD Relay.
Specifications:
•50m detection cable
•Detects water, ethylene glycol
•Detection cable can be dried and reused
Applications:
•Universal water detection in any environment.
•Can be put on the floor, wrapped around pipes, or attached to a wall.
Water leak detection cable A - 2+10m for use with HWg-WLD and HWg-WLD Relay.
Specifications:
•2m connection cable and end terminator
•2m detection cable
•Detects water, ethylene glycol
•Detection cable can be dried and reused
Applications:
•Universal water detection in any environment.
•Can be put on the floor, wrapped around pipes, or attached to a wall.
Water leak detection cable A - 2+10m for use with HWg-WLD and HWg-WLD Relay.
Specifications:
•2m connection cable and end terminator
•10m detection cable
•Detects water, ethylene glycol
•Detection cable can be dried and reused
Applications:
•Universal water detection in any environment.
•Can be put on the floor, wrapped around pipes, or attached to a wall.
Water leak detection cable A - 2+50m for use with HWg-WLD and HWg-WLD Relay.
Specifications:
•2m connection cable and end terminator
•50m detection cable
•Detects water, ethylene glycol
•Detection cable can be dried and reused
Applications:
•Universal water detection in any environment.
•Can be put on the floor, wrapped around pipes, or attached to a wall.
DC current sensor for the 1Wire-UNI bus.
Specifications:
•Input: 0-20mA (connect a “source” type of probe).
•Electrical isolation
•Interface: 1-Wire UNI (2x RJ11 for daisy-chaining)
Applications:
•Connecting industrial sensors to Poseidon2 or Ares systems.
•Connecting current transformers.
DC current sensor for the 1Wire-UNI bus.
Specifications:
•Input: 4-20mA (connect a “sink” type of probe).
•Electrical isolation
•Interface: 1-Wire UNI (2x RJ11 for daisy-chaining)
Applications:
•Connecting industrial sensors to Poseidon2 or Ares systems.
•Measuring fuel level in a tank.
DC voltage sensor for the 1Wire-UNI bus.
Specifications:
•Input: 0-60V DC
•Electrical isolation
•High measuring accuracy (can be used also for 0–10V)
•Interface: 1-Wire UNI (2x RJ11 for daisy-chaining)
Applications:
•Voltage monitoring in telecommunication systems (telco –48V)
•12V or 24V car battery voltage sensor
0-30A AC current sensor for indirect single-phase measurement.
Specifications:
•0-30A AC current range
•Electrical isolation
•Display resolution: 0.1A
•Measured voltage: max. 400V
•Measurement without cutting the L-wire
Applications:
•The sensor can serve as an early warning system against overloading the electricity supply or its individual lines.
A universal water flood sensor detects flood and leackage by soak-detecting cable.
Specifications:
•For STE2, Poseidon2, Damocles2, Ares
•HWg-WLD Relay can be connected as a detector through its digital output or as a sensor via 1Wire UNI bus
•2 to 85 m long sensing cable
•Detection cable monitors even the smallest volumes of electrically conductive liquids. After being flooded with clean water it can be dried and reused.
Applications:
•Detection of water leaking from pipes (cable runs along the pipes)
•Detection cable laid along the walls
•Under raised floors
•Detection of water leaks in drip trays
•Detection of water leaks under A/C outlets
PowerEgg2 detects power failure and switches 230V with a relay.
Specifications:
•For STE2, Poseidon2, Damocles2, Ares
•110-240V AC voltage range
•Turns on/off the 230V/8A output voltage
Applications:
•Alarm activation in case of a power failure
•Monitoring the output voltage of a UPS input/output
•Remote server power up / shutdown
•Emergency cooling / ventilation trigger
Double converter to connect 2 Pt-100/1000 sensores to 1-Wire UNI.
Specifications:
•For Poseidon2 and Ares
•2x Pt-100 or Pt-1000 inputs
•2, 3, or 4 wires sensor connection
Applications:
•Measurement of temperature in a wide range
•Cooling plants with built-in temperature sensors at fixed locations
•Large-scale measurement systems with many measuring points
3 phase 380V M-Bus energy meter for direct measuring (max load 63A). Pulses & M-Bus data output - 3x230V/400V, (5)63A.
Specifications:
•Direct measurement 3x230V/400V, max 63A
•M-Bus interface and S0 interface
Applications:
•For monitoring consumption and supply of active electricity in the
retail / ICT consumption area
•Energy consumption in residential buildings
3 phase 380V M-Bus energy meter for indirect measuring (max load 5A). Pulses & M-Bus data output - 3x230V/400V, 5A.
Specifications:
•Indirect measurement 3x230V/400V, max. 5A
•M-Bus interface and S0 interface
Applications:
•For monitoring consumption and supply of active electricity in the retail / ICT consumption area
•Energy consumption in residential buildings
Single-phase-meter with M-Bus. Pulses & M-Bus data output - 1x230V / 45A.
Specifications:
•Direct measurement 1x230V / 45A
•M-Bus interface and S0 interface
Applications:
•For monitoring consumption and supply of active electricity in the retail / ICT consumption area
•Energy consumption in residential buildings
Drag and Drop Website Builder